How do you use salinity cell cleaner?

Connect the salt cell to a cell stand and pour the muriatic acid solution into the unit. Let the cell soak for 15-20 minutes. If you do not have a cell stand, carefully place the cell in a plastic bucket and add the acid wash solution until the plates are covered. Make sure not to cover the cell electrical connections.

What to do if you get a Jandy error code?

1. Recalibrate salt reading. 2. Backwash your filter if a DE filter is installed. 3. Partially drain your pool and dilute with fresh water until salinity level returns to 3.0. 1. Typically caused by low AC voltage from back board. Check the transformer and back board.

What is code 172 on Jandy aquapure error code?

Salinity sensor sees less than .2 GPL of salt. Either there’s no salt in the pool or sensor is air locked. Flow salinity sensor temperature probe error codes. 1.They all generates code 172- Flow sensor service is required. 2. Perform diagnostic test on board to ensure the board isn’t faulty. If not the board, the tri-sensor is the culprit. 3.

What is the code for Jandy aquapure power supply?

1.They all generates code 172- Flow sensor service is required. 2. Perform diagnostic test on board to ensure the board isn’t faulty. If not the board, the tri-sensor is the culprit. 3. How To Change a Jandy AquaPure Tri-Sensor Front board power supply is either too low or too high. 1. Generates code 173- Low input voltage, IF code 188 is present.

Why is the salinity invalid on Jandy aquapure?

Cell current is 85% lower than desired and cell voltage above 19V. Salinity invalid due to out of range measurements caused by front board error. Although the charts should help narrow down the root to the issue on your Jandy AquaPure unit, it may not completely answer all your questions or concerns.

What does code 170 on Jandy aquapure mean?

Generates code 170 IF 188 is not present. VAC input voltage too low. Relay not conducting in the forward direction. Relay not conducting in the reverse direction. High cell current (at upper limit of A/D converter) and cell voltage falls below 19V. High cell current and cell voltage falls below 19V.

1. Recalibrate salt reading. 2. Backwash your filter if a DE filter is installed. 3. Partially drain your pool and dilute with fresh water until salinity level returns to 3.0. 1. Typically caused by low AC voltage from back board. Check the transformer and back board.

What is the low input voltage code on Jandy aquapure?

(Generates 173 – Low input voltage code if Level 2 code 188 is present) (Generates 170 code if 188 is not present) Contact a pool professional. VAC input voltage is too low. (Generates 173 code if Level II code 187 is present) Contact a pool professional.

Why is there an error code on my Jandy chlorine generator?

It becomes especially difficult if the product, like the Jandy AquaPure Chlorine Generator, only displays an error code, but not necessarily what the error code means nor solutions to the problem. If you purchased the unit a year ago, it’s quite possible you may have misplaced or thrown out the manual. How will you diagnose the issue then?